Proper lubricant installation supports wheel-end performance across the hub cap types covered, including Sentinel® oil applications and stamped-steel hard-pack grease applications. The guidance covers correct fill levels, lubricant placement, and special handling for stamped steel hub caps. It also emphasizes keeping lubricant away from the vent mechanism to avoid cosmetic seepage, filming, or possible vent clogging during initial operation.
Points clés
- Covers lubricant installation for oil, semi-fluid grease, and hard pack grease applications.
- Shows proper oil and semi-fluid grease fill levels for Sentinel® and related hub cap styles.
- Includes semi-fluid grease amounts by application and grease hubcap number.
- Explains how to internally coat stamped steel hub caps with lubricant before installation.
- Repeatedly cautions not to cover the vent mechanism with lubricant.